Komatsu — COLD WEATHER OPERATION

BATTERY As ambient temperature drops, battery capacity will drop, and electrolyte may sometimes freeze if battery charge is low. Maintain battery at a charge level of approx. 100% and insulate it against cold temperature so that ma- chine can be readily started the next morning. Sr Measure specific gravity of fluid and obtain rate of charge from the fol- lowing conversion table: Temp. of fluid Rate of 2o'c O'C -1O'C -2o'c charge 100% 90% 1.26 1.27 1.28 1.29 1.28 1.29 1.30 1.31 80% 75% 1.23 1.24 1.25 1.26 1.24 1.25 1.26 1.27 * When electrolyte level is low, add distilled water in the morning before work instead of after the day’s work. This is to prevent fluid from freez- ing at night.

A To avoid gas explosions, do not bring fire or sparks near the battery. A If the electrolyte gets on your skin or clothes, immediately wash with plenty of clean water. -lOl-