01 Engine 0135 Cooling system ►Open the cooling system only if the coolant temperature is below 90 °C. ►Open the cooling system slowly and relieve the excess pressure. ►Wear protective clothing. ►Unscrew the coolant drain plug carefully and drain coolant. ►Refit the plug immediately after draining. ►Tightening torque: Page 198 1044-004 Filling up ►Top up coolant only as described in the Operator's Manual of the machine in question. Cleaning the coolant circuit ►Start the diesel engine and bring it to operating temperature. Then stop the diesel engine. ►Disconnect the battery isolating switch of the machine. ►Park the machine safely and secure it against rolling away.
►To allow the oil to precipitate upwards, allow a 30- minute rest period. ►Check if there is oil in the cooling system compensating tank. Withdraw coolant from the compensating tank if required and dispose of it properly. ►Drain coolant. Page 198 WARNING! Filling undiluted cleaning concentrate into the cooling system. Damage to cooling system. ►Mix the cleaning concentrate with clear and warm water outside of the cooling system. ►Produce a 3 % cleaning solution with cleaning agent (00 0147 907 0) and clear, warm water. Observe the coolant filling quantity for the machine in question. See the Operator's Manual of the machine in question. ►Remove the compensating tank.
See the repair manual of the machine in question. ►Flush the compensating tank with 3 % cleaning solution. After that, flush the compensating tank with warm water. ►Install the compensating tank. See the repair manual of the machine in question. ►Fill the coolant circuit with 3 % cleaning solution. ►Switch on the battery isolating switch of the machine. ►Set the cab heater to maximum heating capacity. ►Start the diesel engine and heat up the coolant to around 80 °C at medium speed. ►Maintain the coolant temperature at 80 °C for about 5 minutes. 00 0296 433 2 - RHB Dieselmotor OM906/926LA - 10/2014 199