Safety General Information Work on the Common Rail System 1044-004 161964-002 NOTICE Unprofessional installation on Common Rail system. Damage to Common Rail system. ►All work on components of the Common Rail system may be carried out only by specially trained personnel. ►Prior to starting work, the engine must be standing still for at least 5 minutes in order to relieve the pressure in the pressure pipe or pressure reduction must be controlled with the CDS. ►Absolute cleanliness must be ensured during all work in all areas. ►Prior to any work on the clean side of the fuel system, the engine and the engine compartment must be cleaned (e.g.
steam jet cleaner) with the fuel system remaining closed. ►Absolutely avoid moisture. ►Slackened-off inlet connectors must always be replaced. ►Plugs once used for high-pressure lines, pressure pipe and injectors must not be re-used. ►Observe the sequence specified in the description when tightening the injectors, high-pressure lines, pressure pipe and inlet connector. 161966-002 NOTICE Unclosed components. Damage to the Common Rail system. ►Dismount only one fuel line at a time. ►Close the component connections immediately with new and clean caps. Working on the electric system ►Start the engine only with firmly connected batteries.
►Do not disconnect the batteries while the engine is running. ►Do not use any quick-charging devices for starting the engine. ►Assist-starting only with separate batteries. ►The connections of control units may be disconnected and connected only with the electric system switched off. 40 00 0296 433 2 - RHB Dieselmotor OM906/926LA - 10/2014