Komatsu — CHECK AND ADJUST COOLING FAN BELT TENSION

. MAINTENANCE MAINTENANCE PROCEDURE CHECK AND ADJUST COOLING FAN BELT TENSION Adjustment 1. Remove cover (1) between the hydraulic tank and the operator's cab. 4 - 49 Checking If deflection amount " a" shows approx. 8 m m (0.3 in ) when the bel i s p ressed with a thu mb of approx. 58.8 N (6 kg f) force at th midpoint between the alternator pulley and t he fan pulley, t hen it i the standard deflectio n amount. 2. 3. Loosen mounting Open the engine bolt (3) of alternator (2). hood and loosen alternator lock bolt (4). t (5) of alternator (2) in the direction o just the belt tension so that it is approx. 8 mm 4.

Turn tension bol loosening, and ad t (5) of alternator (2) in th just the belt tension so that it i e directio s approx. 8 (0.315 in) (approx . 58.8 N (6 kgf)). do not touch double nut (6). bolt (3) and lock bolt (4). When doing this, do not touch double n 5. Tighten mounting bolt (3) and lock bolt 6. Install cover (1). NOTICE C heck each pulley fo r damage, wear of the V- groove, and wea r of the V-belt. In particular, be su re to check that the V- belt is n ot touching the bott om of the V-groove If the belt is stretche d istributor for replac