MAN — MAN DD13 DD15 Engine Application Installation Manual

COOLING SYSTEM, AIR-TO-AIR CHARGE COOLING 8.3 THERMOSTAT The temperature of the engine coolant is controlled by a single integral full blocking-type thermostat located in a housing attached to the left side of the oil / coolant module. 1. Coolant Return Expansion Tank 2. Coolant Return Cab Heater 3. Water Pump 4. Thermostat Housing Figure 8-3 Thermostat and Related Parts At coolant temperatures below the operating range the thermostat valve remains closed and blocks the flow of coolant from the radiator to the engine. During this period, all of the coolant in the system is recirculated through the engine and is directed back to the suction side of the water pump via a bypass circuit.

As the coolant temperature rises above the start–to–open temperature, the thermostat valve begins to open, restricting the bypass system, and allowing a portion of the coolant to circulate through the radiator. When the coolant temperature reaches an approximate fully open temperature, the thermostat valve is fully open, the bypass system is blocked off, and the coolant is directed through the radiator. 8-4 All information subject to change without notice. DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION