DD PLATFORM APPLICATION AND INSTALLATION MANUAL Cooling is accomplished by incoming air flowing past the tubes and fins of the intercooler. The compressed intake charge flowing inside the CAC core transfers the heat to the tubes and fins where it is picked up by the incoming outside air. Powder coated, painted, untreated mild steel is unacceptable for piping. Aluminum, aluminized steel, stainless steel or fiber reinforced plastic piping is used to transfer the air from the turbocharger outlet to the CAC, and from there to the intake manifold. Flexible rubber couplings and hose clamps are used to secure the duct work to the turbocharger, the CAC inlet and outlet, and the intake manifold.
8.7 COOLING SYSTEM PERFORMANCE REQUIREMENTS Engine heat transferred to the coolant must be dissipated at a sufficient rate so engine coolant temperature does not exceed established safe limits under all operating conditions. The typical maximum engine coolant temperature is 237°F. Specific requirements may be found on www.detroitdiesel.com, if you do not have access to www.detroitdiesel.com contact your Distributor The maximum ambient temperature at which the maximum engine coolant temperature is reached is referred to as ambient capability.
Operating with antifreeze, at high elevation, or other severe environmental conditions will require increasing the cooling capability of the system so the maximum allowable engine coolant temperature is not exceeded. 8.7.1 SYSTEM FILL The cooling system must have sufficient venting (air bleeding) to permit filling at a minimum continuous rate of 3 gal/min. (4.5 L/min) and on an interrupted basis using a 2-3 gallon (10 liter) bucket. The amount of coolant needed to complete the fill must not exceed the satisfactory drawdown amount upon first indication of a full system. This is also a requirement for interrupted fill.
8.7.2 SYSTEM DRAIN Sufficient drains, strategically located, must be provided so the cooling system can be drained to: Prevent freeze problems during cold weather storage Remove all contaminated coolant during system cleaning Minimize refill problems due to trapped air or water pockets 8.7.3 DEAERATION The cooling system must be capable of expelling all entrapped air within 30 minutes while running the engine near rated speed after an initial fill. The water pump must not become air bound. All information subject to change without notice. 8-13 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION