DD PLATFORM APPLICATION AND INSTALLATION MANUAL A digital readout is preferred and should have 12V (DC) and 110V (60Hz AC) capability. A remote multi-channel switch can be wired into the circuit if the readout box does not have sufficient positions for all the thermocouples. Location of the thermocouples is critical. The thermocouples must protrude into a high flow path and not touch surrounding surfaces. Ambient air thermocouples must be shielded from direct sunlight and not sense any radiated or recirculated heat sources. Radiator thermocouples must also be shielded from sunlight. The sump thermocouple must be in the oil while the engine is running.
8.15.2.2 Pressure Gauges and Associated Hardware To measure water pump inlet pressure, use a381 mm Hg to +206.8 kPa (15 in. Hg, +30 psi), compound gage or 72.6 cm (30 in.) or greater “U” type manometer. Additional pressure measurements may be required for analysis of the system. Use a vent at each gage to expel all entrained air and water and ensure no blockage in the circuit. All hoses must be full of the substance being measured. NOTE: Locating gages at the same height as the measurement point eliminates the need to correct the readings. Hose length should be as short as is practical. 8.15.2.3 Thermostat Both blocked open and operating thermostats are required.
A thermostat must be blocked open to the proper dimension for obtaining correct data. Full blocking thermostats must be opened so the coolant bypass circuit is completely shut off. Make a visual check. The oil cooler bypass thermostat must be blocked to the minimum travel distance at full open temperature. Inspect and replace thermostat seals if necessary. All information subject to change without notice. 8-57 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION