DD PLATFORM APPLICATION AND INSTALLATION MANUAL 12. Know cooling system requirements (specifications) for the application and engine configuration to be evaluated. 13. Locate test vehicle or equipment on a level surface for all stationary tests (except high gradeability applications). 8.15.4 TYPES OF TESTS The following tests and evaluations are normally conducted to determine system acceptability: Fill and Capability Tests Continuous Fill Interrupted Fill Total System Capacity Draining Capability Water Pump Air Test Deaeration Test Drawdown Test Water Flow and Pressure Test Cooling Index Test The cooling system must be clean.
Run qualification tests on a finalized complete package installed in unit or vehicle. Perform fill tests with closed thermostats, no pressure cap, and heater, filter circuits, etc. open. The following factors can cause poor filling capabilities and possible water pump air binding problems:
Fill line routing (horizontal) Drooped deaeration lines Incorrect deaeration line location on the engine or deaeration tank Horizontal vortex baffle located on the engine or deaeration tank at fill line opening Routing of coolant lines (drooped) not having a continuous slope Coolant trapped in various cooling system components from a previous fill can prevent air from being purged on the refill Deaeration tank not the highest cooling system component 8.15.4.1 Continuous Fill Perform the continuous fill test as follows: All information subject to change without notice. 8-61 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION