COOLING SYSTEM, AIR-TO-AIR CHARGE COOLING Coolant agitation in deaeration tank High water pump inlet suction Dirty cooling system or contaminated coolant Exhaust gas leak into coolant Water pump seal air leak Determine the expansion and deaeration volume by adding 8% of the total system capacity on top of the cold full level. If this amount of coolant cannot be added to the deaeration tank, cold full level is set too high or the fill neck extension vent hole is not at the top of the tube. If more than 8% can be added, cold full level could be set higher so more reserve coolant volume is available.
8.15.4.8 Drawdown Test The drawdown test should be run with a blocked open thermostat, no pressure cap unless coolant recovery system is used, a site glass in the coolant out line, and coolant at the hot full level. 1. Record the following data while running at rated engine speed (no load speed if rated cannot be held) and after coolant has been completely deaerated. Engine speed Coolant removed Radiator water flow Water pump discharge pressure Water pump inlet pressure (suction) Engine water out temperature Observations for coolant aeration 2. All pressure gages and connecting hoses must be thoroughly bled of air prior to taking data (engine stopped). 3.
Take data with system full and thereafter in 1–quart increments. If system capacity is above 100 quarts, 2–quart increments are acceptable. Remove water from high pressure point, preferable water pump discharge. 4. After each incremental draining, check for signs of air in bleed and fill line (transparent) as well as the radiator (in sight glass). If the bottom of the deaeration tank is not above the rest of the cooling system, stop the engine at each increment and check for coolant level equalization. Restart the engine and run again at rated speed. Look for system aeration. The drawdown rating is determined at the first sign of air. There may not be a loss of flow or pressure at this point.
Continue removing water until a significant amount of aeration occurs or loss of coolant flow (25%-50%) is recorded. 5. Run at maximum tilt angle for installations that operate at severe tilt angles for long periods of time. The drawdown test has been successfully passed if the amount of coolant drained is greater than 10% of system capacity or 4 qt. (3.8 L), whichever is greater. 8-64 All information subject to change without notice. DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION