MAN — MAN DD13 DD15 Engine Application Installation Manual

COOLING SYSTEM, AIR-TO-AIR CHARGE COOLING 8.15.4.9 Water Flow and Pressure Test The coolant flow rate through the engine and/or radiator (heat exchanger) must be within 90% of the values published on www.detroitdiesel.com to ensure proper cooling. Care must be taken so coolant shunted away from the engine or radiator to supply cab heaters, air compressors, auxiliary coolers, wet exhaust systems, etc., are not excessive. Perform the water flow and pressure test with blocked open thermostats, no pressure cap, below 180°F engine water out. Conduct the test with the system at full level and deaerated. 1.

Thoroughly bleed all pressure gages and connecting hoses of air (engine stopped) before recording the following data. Engine speed, radiator water flow, water pump discharge pressure, water pump inlet pressure (suction), and engine water out temperature Observations of bleed and fill lines and deaeration tank (flow, flow direction, aeration) Others — depending on application and complexity of the cooling system 2. Start recording data and observations at idle and then in approximately 300-500 rpm increments up to high no load speed. Be sure data is taken at rated full load speed. 3. Observe fill and bleed line for flow direction, and velocity.

Note if deaeration tank coolant is being agitated causing air to be drawn down fill line. Excessive agitation can be due to bleed line(s) size or location, size and height of the standpipe(s), vent holes in "doghouse" inlet(s), or top tank baffle design. The bleed line(s) should be located low in the deaeration tank (just above baffle) if flow is backwards from the top tank to the engine 4. Check water flow and pump inlet pressure at rated engine speed and determine if they meet the published requirements found on www.detroitdiesel.com, if you do not have access to www.detroitdiesel.com contact your Distributor. NOTE:

If non-factory-supplied engine water components are used, such as wet exhaust manifolds, oil coolers, etc., additional flow measurements may be required to ensure coolant flow through cylinder block and heads has not been seriously reduced. Consult DDC Application Engineering for assistance. 8.15.4.10 Cooling Index Test Perform the cooling index test with a blocked open thermostat and the pressure cap installed. 1.

Determine the cooling index requirement (ATW) by subtracting the maximum ambient temperature, other correction (recirculation & radiation), altitude compensation (corrected to sea level — operating altitude x 1°C per 305 m [2°F per 1000 ft.]), and coolant compensation (3°C [6°F] for 50/50 Ethylene Glycol, 4.4°C (8°F) for 50/50 Proplyene Glycol, 0°C (0°F) for water), from the maximum allowed coolant out temperature. 2. Calculate the cooling index measurement by subtracting the true ambient temperature and the altitude compensation, from the coolant out temperature. 3. Start the test with the cooling system at the deaeration cold full level.

8-66 All information subject to change without notice. DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION