MAN — MAN DD13 DD15 Engine Application Installation Manual

COOLING SYSTEM, AIR-TO-AIR CHARGE COOLING This information will assist in determining system approval and also be a reference point if future difficulties are encountered. 8.15.7 INSTRUMENTATION This section describes the instruments and methods needed to measure the temperatures and pressures of air inlet systems with and without air-to-air charge cooling. 8.15.7.1 Temperature Measurement Use a precision thermocouple and an appropriate read-out device to measure temperatures. Thermocouples should be located downstream of the pressure taps. 8.15.7.2 Pressure Measurement Use a precision gage or a water manometer capable of reading 14 kPa (60 in. H 2 O) for P.

Use a piezometer ring to measure static pressure in straight pipe sections. NOTE: The piezometer ring should be placed within 12.7 cm (5 in.) of the desired measurement location. Figure 8-40 Piezometer Ring 8-72 All information subject to change without notice. DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION