DD PLATFORM APPLICATION AND INSTALLATION MANUAL 8.15.9 INLET SYSTEM RESTRICTION The maximum permitted inlet restriction for a system with a clean air cleaner is 2.5 kPa (10 in. H 2 O). The maximum permitted inlet restriction for a system with a dirty air cleaner is 5.5 kPa (22 in. H 2 O). Restriction should be measured at maximum speed and load. 8.15.9.1 Maximum Temperature Rise — Ambient to Turbocharger Inlet The maximum temperature differential between the ambient temperature and the temperature at the turbocharger inlet (T 1 ) needs to be determined. The temperature differential for the DD Platform engine is 8°C (15°F).

8.15.9.2 Air-to-Air System Evaluation Tests The air-to-air charge cooling system must be tested to verify that engine air intake temperatures and pressure drop limits can be met as shown on www.detroitdiesel.com, if you do not have access to www.detroitdiesel.com contact your Distributor. This evaluation can be done simultaneously with the engine cooling index test. 8.15.9.3 Maximum Temperature Rise — Ambient to Intake Manifold The maximum temperature differential between the ambient temperature and the temperature at the intake manifold needs to be determined. The maximum temperature differential is listed on the Information Highway.

Temperature location is listed in the following table Table 8-6 Thermocouples 8.15.9.4 Charge Air Cooler System Restriction The maximum pressure differential of the charge air cooler system restriction results from the charge air cooler and all of the piping and connections between the turbocharger compressor outlet and the intake manifold. Pressure tap locations are listed in the following table. All information subject to change without notice. 8-75 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION Symbol Measurement Location Description T 1 Air inlet temperature Within 5 in. (12 7 cm) of the turbocharger T 2 Compressor discharge temperature Within 5 in.

(12 7 cm) of the compressor outlet T 3 Intake manifold temperature Within 5 in. (12 7 cm) of the inlet connection T - T 4 8 Charge air cooler core air inlet temperature 5 points in front of the core, one in the center and one at each corner for determining recirculation