DD PLATFORM APPLICATION AND INSTALLATION MANUAL 10.6 OPERATION AND MAINTENANCE The following must be considered for proper operation and maintenance. 10.6.1 FIRST TIME START DD Platform engines are shipped from the factory with a full oil filter and a minimal amount of oil in the sump. The engine needs to be filled with oil to its high limit previous to a first time start. The oil level should be verified after the entire engine installation is complete, to avoid false readings from incorrect angularity during the initial fill.
10.6.2 OIL LEVEL MEASUREMENTS Oil level should always be checked with the vehicle or apparatus on level ground, and any ride-height altering controls set to their rest positions. A minimum wait of ten minutes after engine shutdown is required to achieve an accurate oil level measurement. A twenty minute wait after shutdown is recommended to allow the oil to fully drain back to the pan from the overhead space. 10.6.3 USED OIL ANALYSIS Refer to the Technician's Guide Used Lubricating Oil Analysis , DDC-SVC-MAN-0047, for a detailed procedural description and interpretation of analysis results.
10.6.4 OIL DRAIN INTERVALS For information on oil drain intervals, refer to DDC publication Lubricating Oil, Fuel, and Filters , (DDC-SVC-BRO-0001), on the www.detroitdiesel.com. All information subject to change without notice. 10-7 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION