MAN — MAN DD13 DD15 Engine Application Installation Manual

ELECTRICAL SYSTEM NOTICE: To prevent excessive overrun and damage to the drive and armature windings, the switch should be opened immediately when the engine starts. A cranking period should not exceed 30 seconds without stopping to allow the motor to cool for at least two minutes. Figure 11-3 Cranking Motor Mounting When the engine start circuit is closed, a drive pinion on the armature shaft engages with the teeth on the engine flywheel ring gear to crank the engine. When the engine starts, it is necessary to disengage the drive pinion to prevent the armature from overspeeding and damaging the cranking motor.

To accomplish this, the cranking motor is equipped with an overrunning clutch within the drive pinion. The cranking motor drive pinion and the engine flywheel ring gear must be matched to provide positive engagement and to avoid clashing of the gear teeth. The 39 MT or 42 MT cranking motor typically used on the DD Platform engine has a nose housing that can be rotated to obtain a number of different solenoid positions with respect to the mounting flange. 11-6 All information subject to change without notice. DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION