MAN — MAN DD13 DD15 Engine Application Installation Manual

EXHAUST SYSTEM 6.4.3 MEASUREMENT OF EXHAUST LEAKAGE BETWEEN TURBOCHARGER AND ATD INLET In order to maximize the effectiveness of the ATD, exhaust leaks upstream of the ATD must be kept to a minimum. To accurately measure the exhaust leakage, a bench test is required according to the following procedure: 1. Seal the ends of the exhaust pipe assembly (everything located between the turbocharger outlet and the ATD inlet) with Marmon flange caps. 2. Install an air fitting on one cap supplied with regulated air and a shutoff valve. 3. Install a flow meter to record the air leakage rate in the exhaust piping assembly. 4. Pressurize the exhaust piping assembly to 31 kPa (4.5 psi). 5.

Measure the leakage rate and compare it to the 10 Standard Liters Per Minute (SLPM) per joint specification. 6. The system leakage rate between the turbocharger and ATD inlet should not exceed 30 slpm. 7. No visible smoke/fuel is allowed during a high idle regeneration. 6-12 All information subject to change without notice. DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION