AFTERTREATMENT SYSTEM 7.3 AFTERTREATMENT DEVICE DESIGN FEATURES There are several features, that are designed into the ATD to ease installation and removal of the ATD into chassis at the production level as well as at the service level. Please refer to the specific ATD drawing to get dimensions of all these features and where they are located on each ATD. Figure 7-9 Typical Mounting Views of an Aftertreatment Device 7.3.1 FEET / HOOKS The feet / hooks are designed to serve as the lifting points for the ATD assembly as well as the DPF when separated from the ATD assembly.
When the DPF is separated from the assembly the feet / hooks also prevent the weight of the DPF from being supported by the flanges. Failing to set the DPF on the feet could result in damage to the flanges. They also prevent the ATD assembly and DPF, when separated, from rolling. 7.3.2 LOCATING DEVICE The dowel pin is a locating feature that will allow the ATD to be installed rotationally correct. It is not a mandatory that OEM’s mounting devices (i.e. brackets, straps, etc.) be designed to accept the dowel however it is suggested. Installing the ATD rotationally incorrect will cause stress on inlets and outlets of the ATD as well as the exhaust plumbing and brackets supporting it.
The dowel is not designed to support any load. Utilizing this locating device can prevent the need for secondary operations in a manufacturing environment when aligning exhaust plumbing with the ATD. 7-10 All information subject to change without notice. DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION