Komatsu — CHECK, CLEAN AND REPLACE AIR CLEANER ELEMENT

MAINTENANCE PROCEDURE MAINTENANCE Replacing inner element 1. First remove the outer element, and then remove the inner element. 2. Cover the air connector side (outlet side) with a clean cloth or tape. 3. Clean the air cleaner body interior, then remove the cover from the air intake port in Step 2. 4. Install the new inner element to the body, then tighten the nut. Do not clean the inner element and use it again. NOTICE The inner element must not be used again even after its cleaning. When replacing the outer element, replace the outer element at the same time. 5. Set the outer element in position, then lock cover (3) with hooks (2). 6.

After replacing the element, press reset button (4) of the dust indicator to return the yellow display to its original position. 4-24