MAINTENANCE MAINTENANCE PROCEDURE CLEAN INSIDE OF COOLING SYSTEM 4 q Immediately after the engine is stopped, the coolant is at a high temperature and the radiator is under high internal pressure. If the cap is removed to drain the coolant in this condition, there is a hazard of burns. Wait for the temperature to go down, then turn the cap slowly to release the pressure before removing it. q Cleaning is carried out with the engine running. When standing up or leaving the operator's seat, set the lock lever to LOCK position (L). q For details of starting the engine, see "BEFORE START- ING ENGINE (3-73)" and "STARTING ENGINE (3-89)" in the OPERATION section.
q There is danger of touching the fan if the undercover is left removed. Never enter behind the machine when the engine is run- ning. Clean the inside of the cooling system, change the coolant and replace the corrosion resistor according to the table below. Stop the machine on level ground when cleaning or changing the coolant. Use a permanent type of antifreeze. If, for some reason, it is impossible to use permanent type antifreeze, use an antifreeze containing ethylene glycol. The ratio of antifreeze to water depends on the ambient temperature, but to obtain the corrosion resistance effect, a minimum ratio of 30% by volume is necessary.
When deciding the ratio of antifreeze to water, check the lowest temperature in the past, and decide from the mix- ing rate table given below. It is actually better to estimate a temperature about 10 ° C (18 ° F) lower when deciding the mixing rate.
Mixing rate of water and antifreeze 4-25 WARNING Kind of coolant Cleaning inside of cooling system and changing coolant Replacing corrosion resistor Permanent type antifreeze (All season type) Every year (autumn) or every 2000 hours, whichever comes first Every 6 months (spring, autume) (Drain antifreeze in spring, add antifreeze in autumn) Every 6 months or every 1000 hours, whichever come first Every 1000 hours and when cleaning the inside of the cooling system and when changing coolant Non permanent type antifreeze con- taining ethylene glycol (winter, one season type) When no using antifreeze Min.
atmospheric temperature °C -10 -15 -20 -25 -30 -35 -40 °F 14 5 -4 -13 -22 -31 -40 Amount of antifreeze liter 16.8 20.2 23.0 25.8 28.0 30.2 32.5 US gal 4.44 5.34 6.08 6.82 7.40 7.98 8.59 Amount of water liter 39.2 35.8 33.0 30.2 28.0 25.8 23.5 US gal 10.36 9.46 8.72 7.98 7.40 6.82 6.21 Volume ratio (%) 30 36 41 46 50 54 58