3-28 STARTING SYSTEM INSPECTION (AFTER REMOVAL) INSECTION OF PINION CLEARANCE Carbon pile rheostat 1. Disconnect the wire from M terminal. M S B Ammeter A 2. Connect a 12V battery between S terminal and M Battery terminal. Start motor Voltmeter V 12V 3. If the switch is turned ON, the pinion is moving. CAUTION This test should be done as soon as possible not to damage the coil (in 10 seconds). L4GC344A 4. Measure clearance between the pinion and stopper using a feeler gauge. If the measured value is out of the standard, adjust clearance by adding or removing the washer between the magnetic switch and front bracket.
Stopper Pinion clearance Pinion L4GC345A PULL IN TEST OF MAGNETIC SWITCH S M 1. Disconnect the connector from M terminal. 2. Connect a 12V battery between S terminal and M terminal. CAUTION This test should be done as soon as possible not to damage the coil (in 10 seconds). 3. If the pinion is moving outward, the coil is normal, if or not, replace the magnetic switch. L4GC346A HOLD IN TEST OF SOLENOID 1. Disconnect the connector from M terminal. S M 2. Connect a 12V battery between S terminal and M terminal. CAUTION This test should be done as soon as possible not to damage the coil (in 10 seconds). 3.
If the pinion is moving outward, the coil is normal, if the pinion is moving inward, replace the magnetic switch owing to open-circuit. L4GC361A Pinion clearance 0.5 ~ 2.0mm