Hyundai Construction Equipment — l4gc

STARTING SYSTEM 3-29 RETURN TEST OF SOLENOID S M 1. Connect the connector from M terminal. 2. Connect a 12V battery between S terminal and M terminal. CAUTION This test should be done as soon as possible not to damage the coil (in 10 seconds). 3. When releasing after pulling the pinion outward, if the pinion is returned to native position, it is normal, if or not, replace the solenoid valve. L4GC362A PERFORMANCE TEST (WITH NO-LOAD) 1. Connect a 12V battery to the start motor. Switch 2. To operate the start motor with no load, turn the switch ON. If the operating speed and current measured are identified with the standard, the start motor is normal.

If the operating speed is insufficient or the current is excessive, it is be- cause of excessive friction resistance. And the low current or lack of operating speed is because of faulty contact or open circuit between the brush and the rectifier or between the welding points. Armature Carbon pile rheostat Start motor Battery 12V Voltmeter L4GC347A Snap ring DISASSEMBLY To remove the overrunning clutch from the armature shaft, re- move the stop ring. Remove the stop ring by moving it to the pinion side, and then remove the stop ring from the shaft. Stop ring L4GC342A INSPECTION (AFTER DISASSEMBLY) 1.

GROUND TEST OF ARMATURE COIL Check continuity between the commutator and the arma- ture coil using a circuit tester. If there is continuity, replace the rotor assembly. L4GC349A Speed Minimum 3,000rpm Current Maximum 60A or less