3-30 STARTING SYSTEM 2. SHORT CIRCUIT TEST OF AMARTURE COIL Inspect the armature coil in the growler and if there is short circuit, replace the coil. During core rotation, if the blade attached in the core is vibrated, the armature is short. L4GC350A 3. OPEN CIRCUIT TEST OF ARMATURE COIL Check continuity between the commutator segments using a circuit tester. If there is no continuity, replace the arma- ture assembly owing to open circuit of commutator segment. L4GC351A 4. OPEN CIRCUIT TEST OF FIELD COIL Check continuity of the field coil using a circuit tester. If there is no continuity, replace the field coil assembly owing to open circuit of the field coil. L4GC352A 5.
GROUND TEST OF FIELD COIL With the yoke field coil installed, inspect continuity between the field coil and the yoke, if there is continuity, replace the field coil. L4GC353A