John Deere 450H, 550H, 650H — Clean or Replace Winch Hydraulic Breather Filter—If Equipped

Maintenance—Every 1000 Hours Clean or Replace Winch Hydraulic Breather Filter—If Equipped The breather filter is located in the right service compartment. 1. Loosen clamp cap screw. 2. Remove hose (1) from breather filter (2). 3. Using compressed air, clean filter. If filter can not be cleaned, replace filter. 4. Install hose end on filter making sure arrow points in same direction (toward reservoir). 5. Tighten clamp (3) with cap screw. 1— Hose 2— Breather Filter 3— Clamp T121231B —UN—20APR99 550H Shown CED,OUO1047,4 -19-10MAY99-1/1 3-8-5 070813 PN=113