Maintenance—Every 2000 Hours 4. Remove filter (A) by turning counterclockwise. 5. Apply thin film of oil to gasket of new filter. 6. Install new filter. Turn filter clockwise by hand until gasket touches mounting surface. 7. Tighten additional 1/2 turn. T117893B —UN—03NOV98 8. Fill reservoir with oil. See Transmission and Hydraulic Specification Hydraulic Oil Reservoir—Capacity......................................32 L (8.5 gal) Approximate Oil. (Section 3-1.) 9. Check O-ring on fill cap and install fill cap. 10. Start engine and run for 2 minutes. Stop engine and check for leaks around filter base. Tighten filter only enough to stop leaks. A—Filter B—Sight Tube 11.
Check oil level in sight tube (B). Oil level must be between the ADD and FULL marks on tube. If necessary, add more oil. CED,OUO1032,1125 -19-02NOV98-3/3 Change Transmission Oil and Filter 1. Transmission hydrostatic reservoir, filter and drain are located on left side of machine. Remove fill cap (B). B—Fill Cap T117892B —UN—26OCT98 Continued on next page HG31779,00000D0 -19-06JUN05-1/3 3-9-2 070813 PN=115