John Deere 450H, 550H, 650H — Removing Batteries

Miscellaneous—Machine See your authorized dealer for JT05460 SERVICEGARD™battery and coolant tester. Follow directions included with the tester. A fully charged battery will have a corrected specific gravity reading of 1.260. If the reading is below 1.200, charge the battery. T85402 —UN—10NOV88 Battery And Coolant Tester SERVICEGARD is a trademark of Deere & Company TX03679,0001788 -19-29APR11-2/2 Replacing Batteries The dual battery option is required when the ambient temperature is below 0°C (32°F). Batteries are located in left side service compartment. CAUTION: Sulfuric acid in battery electrolyte is poisonous.

It is strong enough to burn skin, eat holes in clothing, and cause blindness if splashed into eyes. TS281 —UN—15APR13 Avoid the hazard by: 1. Filling batteries in a well-ventilated area. 2. Wearing eye protection and rubber gloves. 3. Avoiding breathing fumes when electrolyte is added. 4. Avoiding spilling or dripping electrolyte. 5. Using proper jump start procedure. If you spill acid on yourself: T117482 —UN—20OCT98 1. Flush your skin with water. 2. Apply baking soda or lime to help neutralize the acid. 3. Flush your eyes with water for 10—15 minutes. Get medical attention immediately. Dual Battery Option Shown If acid is swallowed: 1. Drink large amounts of water or milk. 2.

Then drink milk of magnesia, beaten eggs, or vegetable oil. 3. Get medical attention immediately. Your machine will have one or two 12-volt batteries with negative ground. Use only batteries meeting the following specifications: TX,90,RB82 -19-14JAN08-1/1 4-1-6 070813 PN=122 Single Battery Battery Group 31 925 cold cranking amps at –18°C (0°F) 190 minutes reserve capacity at 25 amps Dual Battery—If Equipped Battery Group 31 1850 cold cranking amps at –18°C (0°F) 380 minutes reserve capacity at 25 amps