Komatsu — METHOD OF USE

. ATTACHMENTS, OPTIONS HANDLING OIL FILTER CAUTION Display items for oil filter replacement interval Timer switch related items (1) (2) (3) (4) (4) (5) (6) (7) (8) (9) Engine oil Transmission oil Hydraulic oil Final drive case oil Differential case oil Engine oil filter Fuel filter Corrosion resistor Transmission oil filter Hydraulic filter (10) (11) (12) (13) (14) Maintenance timer Replacement interval check switch (oil) Replacement switch Cancel switch Replacement interval check switch (filter) METHOD OF USE CHECK BEFORE STARTING These all light up for 3 seconds when the starting switch is turned ON, and after 3 seconds, only the items requiring maintenance stay lighted up or flash.

For details of the meaning of lighted or flashing lamps, see Section "SERVICE PROCEDURE (PAGE 4-22)" and replace the oil or filters. ABNORMALITY DISPLAYED DURING OPERATION If any abnormality occurs during operation, this lamp flashes. Note that it flashes when the filters are clogged and lights up when the replacement interval has passed. 6 - 49 HANDLING OIL FILTER CAUTION The oil filter caution is a d evice to warn the operator by using a c autio n lam p to i nform that the filter is clogged o r that the replacement interval for the oil or filters has passed.