Lubrication and Service - Section 40 9/11 OM4057 Page 40-16 1,000 HOURS LUBRICATION AND MAINTENANCE CHECKS (cont.) 7. 8. 9. 10. TASK COMMENTS CHECKED INITIALS INVERTER CABINET RADIATOR COOLING PUMP - Add one or two applications of grease to each bearing grease fitting. Ensure that each bearing is receiving grease. (Lube Key E) IGBT CONTROL BOX - Clean out the cabinet radiator. - Remove any dirt or debris from the transformer with a small brush and a vacumm. ELIMINATOR FILTER - Clean and check centrifuge. Refer to engine manufacture’s Operation & Maintenance Manual. (Service interval is dependent on duty cycle, oil quality, etc.).
AUTOMATIC LUBE SYSTEM PUMP - Check pump housing oil level using dipstick on top of the pump unit (or oil level plug on side). If necessary, add SAE 10W- 30 motor oil.