Komatsu — Pump Pressure Control

Automatic Lubrication System - Section 42 10/10 OM4212 Page 42-6 LUBRICANT PUMP Pump Housing Oil Level The pump housing must be filled to the proper level with SAE 10W-30 motor oil. Check the oil level at at the 1,000 hour maintenance interval. To add oil, remove dipstick (4, Figure 42-5) on top of the pump housing and fill the housing to the proper level marked on the dipstick. Pump Pressure Control High pressure hydraulic fluid from the truck steering system is reduced by the pressure reducing valve located on the manifold on top of the pump motor. This pressure can be read if pipe plug (3) is removed and a gauge is installed on the manifold. FIGURE 42-5. AUTO LUBE PUMP CONTROLS 1.

Pump Pressure Control 2. Override Switch 3. Pipe Plug 4. Dipstick 5. Flow Control Valve