Komatsu — SYSTEM TROUBLESHOOTING CHART

Automatic Lubrication System - Section 42 10/10 OM4212 Page 42-12 TROUBLE POSSIBLE CAUSES SUGGESTED CORRECTIVE ACTION Pump Pressure Builds Very Slowly Or Not At All No signal at solenoid. Check wiring for open circuit. Also check for fault codes on dash panel display. Controller Does Not Operate No electric power to controller. Turn on electric power to pump. “POWER” LED should light, “PUMP ON” LED should light when “MANUAL LUBE” is pressed. Bearing Points Excessively Lubricated Lube cycle interval set to low. Select larger lube cycle interval. Injector output adjustment setting too high. Readjust to lower setting.

Bearing Points Are Not Sufficiently Lubricated Lube cycle interval set to high. Select smaller lube cycle interval. Injector output adjustment setting too low. Readjust injector output setting. System too large for pump output. Calculate system requirements per planning manual.