OM6012 2/11 Payload Meter III - Section 60 Page 60-3 Operator Switches In addition to toggling through warning screens and various truck information, the operator switches can be used to set, view and clear the total load counter and total ton counter of the payload meter. It is also used to enter the operator ID number (0-9999) and view the suspension pressures and inclinometer. Payload Meter The payload meter is housed in a black aluminum housing. There is a small window on the face of the unit. Status and active alarm codes can be viewed through the window. During normal operation, a two- digit display flashes 0 back and forth. Active fault codes will be displayed for two seconds.
These codes are typically viewed using the laptop computer connected to the serial communications port. The operator switches are two-way momentary switches located on the lower left hand dash panel. The arrow positions are used to step through the different displays. The OK position is used to set the operator ID or clear the load and total ton counters. Normally, the inputs from the switches to the payload meter are open circuit. For more information of these switches refer to Operator and Cab Controls, Section 32, of this manual. There is one 40-pin connector on the payload meter. A jack-screw is used to hold the payload meter and wire harness connector housings together.
This screw requires a 4mm or 5/32 in. hex wrench. The tightening torque for this screw is 3 N•m (25 in lbs) . Four bolts hold the payload meter housing to its mounting bracket in the cab. The circuit board inside the payload meter housing is made from multi-layer, dual-sided surface-mount electronics. There are no field serviceable components inside. The electronics are designed to withstand the harsh operating environment of the mining industry. Opening the payload meter housing will result in voiding the warranty. Speed Input PLMIII uses a speed signal to calculate speed, distance, and other performance data. This input is critical to the proper operation of the system.
PLMIII receives this signal from the speedometer/load display on the instrument panel. The same signal displayed to the operator is used by the system. Distance calculations are made based on the rolling radius of the tires for a particular truck. Communications Ports The payload meter has two RS232 serial communications ports and two CAN ports. Connections for the two serial ports are available inside the payload meter junction box. The two CAN ports are available for future electronics systems. Body-Up Switch The body-up input signal is received from a magnetic switch located on the inside of the truck frame, forward the pivot pin of the truck body.
This is the same switch typically used for input to the drive system. When the body is down, the switch closes and completes the circuit to 71-control power. 24VDC indicates that the body is down. Open circuit indicates that the body is up. Serial port #1 is used to communicate with the dashboard display. It is also used to connect to the laptop computer. The display gauge will remain blank when the PC is using the serial port. This port initially operates with serial settings at 9600,8,N,1. These settings change automatically to increase the communications rate when the PC is using the port. This serial port uses a 3-wire hardware connection.
Brake Lock Switch Serial port #2 is used to communicate to other on- board electronics like Modular Mining's Dispatch ® The brake lock is used to lock the rear brakes on the truck. It is necessary for the accurate calculation of swingloads during the loading process. Without the brake lock applied, the payload meter will not calculate swingloads during the loading process. Without the brake lock, the payload meter will assume that the truck was loaded using a continuous loader and flag the haul cycle record. All other functions will be normal regardless of brake lock usage. The brake lock input comes from the switch located on the dash panel.
The brake lock switch connects the circuit to ground. Open circuit indicates that the brake lock is off. Ground indicates that the brake lock is on. system or the scoreboard from Komatsu. This port uses a 3-wire hardware connection. Connections to this serial port need to be approved by Komatsu. Several protocol options are available and detailed technical information is available depending on licensing.