OM6012 2/11 Payload Meter III - Section 60 Page 60-5 LOAD DISPLAY AND OPERATOR SWITCHES Total Ton and Total Load Counters PLMIII allows the truck operator to monitor and track the total tons hauled and the number of haul cycles during the shift. This display can be cleared at the beginning of each shift to allow the operator to record how many loads and tons have been hauled during the shift. The top display on the speedometer/load display is the speedometer and can display metric (km/h) or English (mph) units. See “Digital Display Operation” in Section 32 for instructions on setting the displayed units.
The speedometer can be adjusted using a calibration potentiometer in the back just like existing speedometers. To view the total ton and total load counters, refer to Digital Display Operation - Toggling Through Main Level Screens in Section 32, Operator Cab and Controls. Follow the flow chart to the desired payload meter information screen. The lower display on the speedometer/load display is used for payload information. Use the operator switches to scroll to the “PAYLOAD DATA” main level screen, then through the following payload meter information displays: The total ton counter records the number of tons hauled since the last time it was cleared. This display is in 100’s of tons.
For example, if the display shows 432 , the total tons is 43,200. This display can be cleared at the beginning of each shift to allow the operator to record how many tons have been hauled during the shift. The units are selected using the PC software. Operator ID Total Shift Tons Shift Load Counter Suspension Pressures and Inclinometer The total load counter records the number of loads hauled since the last time it was cleared. This display can be cleared at the beginning of each shift to allow the operator to record how many loads have been hauled during the shift. The display holds the operator ID and total shift tons information until the OK position of the operator switch is pressed.
The suspension pressures, inclinometer, and payload displays are based on current sensor inputs. Clearing the total ton counter or total load counter clears both records. Communications to the display use the same serial link as the download connection. Whenever another computer is connected to serial port #1 to download or configure the system, the lower display will blank. This is not the same connection used by mine dispatch systems. To clear the total ton and total load counter, press the OK position of the operator switch while viewing this screen.
Viewing Live Sensor Data The display can also be used to quickly show the current readings from the four suspension pressure sensors and the inclinometer. This can be used during regularly scheduled service periods to check the state of the suspensions. These displays are live and will update as the values change. The current operator ID number is recorded with each haul cycle. The number can be between 0 and 9999. Setting the Operator ID To set the operator ID, use the arrow positions of the operator switches to scroll to the “PAYLOAD DATA” main level screen. Then refer to Digital Display Operation - Entering Payload Meter Data in Section 32, Operator Cab and Controls.
Follow the flow chart, substituting your operator ID for the one in the example. The live displays cannot be cleared and the OK position of the operator switch will have no effect. The units for the display are controlled by the configuration of the payload meter. If the payload meter is set to display metric units, the pressures will be displayed in tenths of kg/cm 2 . For example, if the display shows 202 , the actual value is 20.2 kg/ If no buttons are pressed for 30 seconds, the display will return to normal operation. The number being entered will be lost and the operator ID returns to the previous number. cm 2 .
If the payload meter is set to display short tons, the pressures will be displayed in psi (lbs/in 2 ). Multiply by 14.2 to convert kg/cm 2 to psi. (example -- 1kg/cm 2 x 14.2 = 14.2 psi). There is no way to detect the units setting for the gauge without the PC software.