OM6012 2/11 Payload Meter III - Section 60 Page 60-7 The payload meter switches from loading state to maneuvering state as soon as the truck begins moving. The maneuvering zone is 160m (0.1 mile) and is designed to allow the operator to reposition the truck under the shovel. More payload can be added anytime within the maneuvering zone. Once the truck travels 160m (0.1 mile) the payload meter switches to the final zone and begins calculating payload. If the body is raised while the payload meter is in the maneuvering state, the no_final_load flag will be recorded in the haul cycle record, no payload will be calculated, and the meter will switch to the dumping state.
Load Calculation The final load calculation is different from the last swingload calculation. The accuracy of the swing load calculation depends on loading conditions and the position of the truck during loading. The last swingload calculation is not the value recorded in memory as the final load. The final load is determined by a series of calculations made while the truck is traveling to the dump site. Carry Back While in the final zone, and moving faster than 5 km/ h (3 mph), the payload meter calculates the loaded sprung weight of the truck. The same advanced algorithm is used to calculate the empty and loaded sprung weights.
The payload meter will switch from the final zone to the dumping state if the body-up signal is received. If the truck has moved for less than one minute in the final zone, the payload meter will calculate the final payload using an averaging technique which may be less accurate. If this happens, the average_load flag will be recorded in the haul cycle. Carry back is calculated as the difference between the current truck tare and the clean truck tare. The clean truck tare is calculated using the PC software. When the suspensions are serviced or changes are made that may affect the sprung weight of the truck, a new clean truck tare should be calculated.
Measurement Accuracy Payload measurements are typically repeatable within 1%. Accuracy for a particular scale test depends on specific combinations of pressure sensors and payload meters as well as the specifics of each scale test. Comparisons from different scale tests are often made without considering the differences introduced by the specific installation and operation of the scales for each test. In addition, each pressure sensor and payload meter introduces it's own non-linearity. Each truck becomes an individual combination of sensors and payload meter.
Errors from these sources can introduce up to a ±7% bias in the payload meter calculations for a specific scale test, for an individual truck. The payload meter switches to the dumping state when the dump body rises. The payload meter will switch from dumping state to after dump state when the dump body comes back down. From the after dump state, the payload meter will switch to one of three states: 1. If the average payload is greater than 20% of rated load and no final payload has been calculated, the payload meter will return to the maneuvering state. After the truck travels 160m (0.1 mile) the meter will switch to the final zone and attempt to calculate the payload again.
The false_body_up flag will be recorded in the haul cycle record. Because the PLMIII calculates a new empty tare for each payload, a detailed scale test must weigh the trucks empty and loaded for each haul cycle. Using a simple average of two or three empty truck weights as an empty tare for the entire scale test will introduce significant error when comparing scale weights to PLMIII weights. 2. If the average payload is greater than 20% of rated load and the final payload has been calculated, the payload meter will switch back to the hauling state. The false_body_up flag will be recorded in the haul cycle record. 3.
If the average payload is less than 20% of rated load, the payload meter will switch to the tare zone and begin to calculate a new empty tare.