Weichai — Weichai WD10 Diesel Engine Service Manual

Service Manual for WD10 Diesel Engine 48 Cooling System 481 Disassembly and Assembly of Cooling System 4811 Exploded View of Cooling System The function of cooling system is to ensure diesel engine can continuously work at proper temperature. Forced circulation cooling offers the best guarantee to keep the engine in normal operating temperature, which mainly consists of water pump, fan, expansion water tank, water tank and thermostat. Generator support module F a n Oil dipstick module Tensioning wheel and belt module Fan and hub module Pulley and damper module Air compressor module Fig. 4-61 Exploded view of cooling system 4812 Steps to Disassemble Cooling System As shown in Fig. 4-61:

(1) Remove fan and hub, refer to disassembly of fan for details. (2) Remove the tensioning wheel. (3) Remove the belt. 99 Water pipe joint module Thermostat module Water pump module Hydraulic pump module Generator module