Weichai — Weichai WD10 Diesel Engine Service Manual

Service Manual for WD10 Diesel Engine (5) A/C compressor leakage detecting process: 1) Remove the A/C compressor if find out the compressor has leakage problem during the maintenance. 2) Prepare air source or nitrogen gas cylinder, high pressure gas of 3MPa is required. 3) Prepare vessel for leakage detection, the vessel should be big enough to hold the compressor, pour water or ethyl alcohol into the vessel. 4) Prepare connector to connect the compressor and air source. O-shape seal ring is required for connecting the connector and compressor. 5) Connect the connector to compressor and fix it with bolts, inflate compressor with high pressure gas to 1.5~1.8Mpa.

6) Put the inflated compressor into vessel and observe, there is no leakage problem if bubble doesn’t occur in 5min; if bubble occurs, marking the bubbling position with marker pen. (6) Precautions for A/C compressor leakage detecting: 1) Note that the inflating pressure should not be too high. 2) Wear google to protect your eyes in the leakage detecting process. 3) Ensure enough observing time to avoid neglecting minor leakage. 4) After the detecting, check whether there is air in the compressor to prevent confusion.

136 5) Positive pressure inspection method After maintenance but before filling refrigerant, add a small amount of gaseous refrigerant and inflate the system with nitrogen to 1.4~1.5MPa, maintain the pressure for 12h. If pressure drop exceeds 0.005MPa, then it indicates that there is system leakage. Find out the leaking position with soap-suds. 6) Negative pressure inspection method Pump the system into a vacuum, and check vacuum gauge after a while, if vacuum degree drops, then there must be leakage.