Service Manual for WD10 Diesel Engine 135 1) Visual inspection method Refrigerant and freezing engine oil are mutually soluble, so there must be oil trace at the leaking site (but slight oil trace in compressor shaft seal is normal). When refrigerant leakage occurs, freezing engine oil generally leaks along with the refrigerant. Pay attention to hose joints and components that covered by oil dirt for leakage detection. 2) Soap-suds inspection method Apply the to-be inspected part with soap-studs, bubble will occur if there is leakage. 3) Dye inspection method Fill dyed refrigerant into the system, and colored trace will occur if there is leakage.

This method can also be used to detect minor leakage, but will leave many impurities in the A/C system. 4) Electronic device inspection method Turn on the electronic leak detector and it will produce small “Didi” sound, when a leakage is detected, frequency of the “Didi” sound will increase. There are many ways to operate the electronic leak detector, the most common one is: Approach the probe to the component or joint (about 5mm). Avoid direct contact, otherwise error reading may occur, even damaging the probe.