www.changlin.com.cn 10 mm Hex Drive Caution: If a replacement or repaired pump was installed, be sure to fill the governor housing with engine oil before starting the engine. Failure to do so will result in damage to the governor fly weights. Remove the access plug. Oil Capacity RQVK Governor 750 ML [0.71 Qt] Install the access plug. Torque Value: 28 N-m [21 ft-lb] Injection Pump‐Idle Speed Adjustment RQVK Governor 10 mm Screwdriver and Tachometer Idle adjustment on automotive pumps requires setting of the stop screw. Loosen the locknut and turn the screw counterclockwise to raise the RPM; clockwise to decrease the idle speed Tighten the lockscerw. 132 / 167 pages