TIC LEXION 480-405 Front attachment Key to diagram 407 - Restrictor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ш 1.0 mm 734 - One-way valve (lock-up valve unit) Y79 - Solenoid valve for table forward Y80 - Solenoid valve for table backward T - Tank port P1 - Pump port via returns valve A3 - Hydraulic ram port for table adjustment . . . . Ш 40/20 mm B3 - Hydraulic ram port for table adjustment . . . . Ш 45/20 mm K - Plunger Both sides of the rams are tightly locked up by the one-way valves (734) at ports A and B. Function – neutral Function When required the relative solenoid valve (Y79/Y80) is operated, and at the same time the returns valve is also opened.
The relative spool pushes the ball off its seat and at the same time closes the flow to tank. The pressure then flows down to the lock valve, then builds up and presses on the plunger. The plunger (K) then operates the opposite one-way valve (734) on port A or B. The return oil from the ram, then flows back to tank via the valve insert of the non switched solenoid valve (Y79/Y80). The pressure then builds up and operates the second one-way valve (734). The oil then flows out of the port and to the hydraulic ram which travels in or out. 03/2004 5-29