CLAAS LEXION II (480 - 405) — gb 00 Deckblatt

CLAAS ACADEMY LEXION II Low pressure hydraulics Key to diagram 729 - Pressure relief valve (mounted on tank from year 2001 on) . . . . . . 19 +4 bar T - Connection to tank P - Connection to the charge pump of the hydrostatic drive A - Connection to the hydraulic ram V - Valve insert S - Screw for emergency operation Function When the solenoid is switched off, the flow of oil comes from the ram (A) through the valve unit (V) and back to tank (T). The low pressure (P) is effectively locked by the ball in the valve insert (V). When the solenoid is energised, the ball is pressed off its seat within the valve insert (V) and closes the flow back to tank (T).

The low pressure (P) then flows through the valve and out of the port (A). Note: In an emergency, the screw (S) can be used to press the ball off its seat and to close the return to tank (T). A - from 2001 B - up to 2002 Pressure relief valve 11/2001 6-11