CLAAS LEXION II (480 - 405) — gb 00 Deckblatt

TIC LEXION 480-405 SAUER hydrostatic drive Key to diagram 214 - Actuating pressure backward measuring port . . . . . . . . . . . . . . . . . . . . . . . . M5 215 - Actuating pressure forward measuring port M4 218 - High pressure forward measuring port . . . . M1 219 - High pressure backward measuring port . . M2 223 - Feed pressure measuring port . . . . . . . . . . . M3 Pressure settings M1 - 9/16” – 18UNF 2B, O ring . . . . . . . . . . . . . . . 30-420 +30 bar M2 - 9/16” – 18UNF 2B, O ring . . . . . . . . . . . . . . . 30-420 +30 bar M3 - 9/16” – 18UNF 2B, O ring . . . . . . . . . . . . . . . 30 ± 2.5 bar M4 - 9/16” – 18UNF 2B, O ring . . . . . . . . . . . . . . .

0-37 ± 2.5 bar M5 - 9/16” – 18UNF 2B, O ring . . . . . . . . . . . . . . . 0-37 ± 2.5 bar Charge pressure – pressure relief valve Once the lock nut has been slackened, then the charge pressure – pressure relief valve can be adjusted. One turn of the adjustment will change the setting by approx. 3.5 bar . Multifunction valve On the multifunction valve only the pressure separator can be measured and set. The value of the high-pressure should be in the region of approx. 30 bar above the pressure separator. After slackening off the lock nut on the multifunction valve, the pressure can be adjusted. One turn of the adjusting screw will change the pressure by approx. 93 bar .

Purge valve The quantity of oil purged is dependant on the restrictor hole in the valve and is set to approx. 25 to 30 l/min at normal speed and normal pressure. System leaks about 2 to 3 l/min and is checked with a volume flow meter. Purge valve Only to no. 466-0165 no. 454-0805 Systems with an adjustable purge valve, should be adjusted to give a charge pressure drop of min 2.5 bar / max 4 bar . For this adjustment, it is required that the gear lever is in neutral and the hydrostatic lever is pressed out fully. This ensures that the shuttle valve is switched. Note:

For all readings and adjustments, the engine should be in fast idle and the hydraulic oil is at working temperature of at least 60°C. 03/2004 7-13