CLAAS LEXION II (480 - 405) — gb 00 Deckblatt

TIC LEXION 480-405 SAUER hydrostatic drive High-pressure circuit As soon as the pump (217) is swashed, there is an axial movement of the pump components. Due to the axial movement the oil in the cylinder area of the rotors and act like a motor (220), the energy over the support of the swash plate and in one turning moment. The relative suction side of the pump (217) is pressurised via the charge pressure from the relative valve in the multifunction valve (211/212). This ensures that the pump (217) oil supply is maintained, irrespective of the internal leaks.

On the suction side of the pump (217) as with the return side of the motor (220), there is always charge pressure, should this become the high-pressure and not the low-pressure side. Pressure cut-off Should the high press exceed the allowed amount, then the relative pressure cut-off valve in the multifunction valve (211/212) opens, and allows the oil to flow to the opposite side, which has the control pressure for the servo ram (216). This return control pressure is limited over the charge pressure valve (205) and then over the control pressure, pressure relief valve (206). This will lead to a greater control pressure than can be allowed.

As a result, the pump (217) is swashed back slightly, the pressure cut-off is closed, which balances the swash plate to maximum pressure. Because of the fact that the oil, during the oil cut-off, is released over a valve, the oil will get rather warm. High-pressure control The spikes in the system, that cannot be released in the cut-off valve are released in the high pressure valve in the multifunction valve (211/212) and into the charge pressure line. The high-pressure control works independently to the setting of the cut-off valve and cannot be tested.

Purge control In the relative high-pressure side, the shuttle valve (221) in the motor (220) is switched, so that the relative low-pressure side has a connection to the motor housing via the purge valve (222). Because of the fact that the pressure setting of the purge valve (222) is lower than that of the charge pressure control (205), a constant oil flow is present through the purge valve (222) and the charge pump (201). 03/2004 7-21