TIC LEXION 480-405 SAUER hydrostatic drive Servo control valve The cable from the hydrostatic lever (F) adjusts the control spool (S) in the servo control valve, and moves it out of the neutral setting in one direction or the other. The selected travel direction, will create pressure (P) on one side (A/B) and on the other (B/A) is connected to the return line back to tank (T). The servo ram swashes the pump only by the amount selected by the hydrostatic lever (F) and the mechanical response (R) ensures the swash angle of the control spool (S) in servo control valve which acts on the edge thus holding the angle. Adjusting the hydraulic neutral adjustment:
So that the neutral adjustment of the hydrostatic lever (F) can be set with the neutral adjustment on the motor, the control spool (S) on the servo control valve is equipped with an adjusting screw (N). Turn the screw (N) in both directions, until on ports (M1/M2) a pressure reading is obtained and mark to two positions. Then position the screw (N) in between the two marks. Multifunction valve I - Pressure cut-off: Through the restrictor holes in the valve plate, stands the high pressure (H) against the valve pin (1). Should the pressure exceed permitted limits, then the pressure presses the pin against the spring, which then opens the valve (1) and releases the oil (A).
II - High-pressure control: When a spike in system (H) pressure, a momentary build up of pressure is standing at the restrictor hole in the valve plate and over in the spring portion. This causes the inner valve (2) to open against the spring and allow the peak of pressure to be released into the charge pressure circuit (S). This happens before the pressure cut-off (A) valve (1) has opened. III - Charging: As soon as the high pressure (H) against the valve plate is lost, the charge pressure (S) presses the outer valve (3) upwards. This causes the inner valve (2) to open against the spring and allow the charge pressure (S) to flow into the low-pressure side (N). 03/2004 7-25