CLAAS LEXION II (480 - 405) — gb 00 Deckblatt

TIC LEXION 480-405 SAUER hydrostatic drive Key to diagram 230 - Shuttle valve pilot oil 231 - Solenoid valve 4 wheel drive engagement 232 - Main 4 wheel drive engagement valve 233 - Forwards flow control valve 234 - Reverse flow control valve 235 - Lock valve 238 - Restrictor for engagement 239 - Restrictor for disengagement A - Pump for forwards A1 - Right hand wheel motor for forwards A2 - Left hand wheel motor for forwards B - Adjustable pump for reverse B1 - Right hand wheel motor for reverse B2 - Left hand wheel motor for reverse S - Charge pressure T - Return to tank Function (see also page 7-4) Depending on the high-pressure side, the high-pressure line (A/B) will switch the shuttle valve (230), so that over the respective low-pressure side is always charge pressure on the solenoid valve (231).

Depending on the switching of the solenoid valve (231) will determine if the control spool (232) travels OUT or on the opposite side IN to supervise the charge pressure. The control spool (232) supplies the oil (A/B) to the relative flow control valve (233/234) for the wheel motor on the connection A1-A2 or B1-B2. The return oil flow from the wheel motors B1-B2 or A1-A2 flows back via the lock valve (235) on the other side, and then back to the low-pressure side (B/A). The flow control valves (233/234) control the oil flow to the wheel motors, in order to equal the amount of oil should one or both of the wheel motors hit light going.

The wheel motor with the larger load creates a pressure build up against the flow control spool, and act on the control edge of the opposite side which closes and consequently which then balances out both sides. 03/2004 7-29