TIC LEXION 480-405 Standard machine functions Key to diagram 614 - Flow control valve . . . . . . . . . . . . . . . . . . . . . . . . 5 – 50 l/min. 703 - Pressure relief valve . . . . . . . . . . . . . . . . . . . . . . 175 +15 bar 732 - One-way valve (delivery valve) 901 - Working hydraulics test port Y77 - Master valve solenoid valve Y85 - Solenoid valve for raising the front attachment Y87 - Solenoid valve for lowering the front attachment A1 - Hydraulic ram for raising / lowering the front end attachment T - Connection to tank P - Connection to pump P1 - Parallel connection to other valves H - Spool for raising the front end attachment K - Plunger R - Control spool . . . . . . . . . . .
. . . . . . . . . . . . . . . . 5-50 l/min S - Return valve for lowering the front end attachment U - Spool for the returns valve V - Control valve D - Shims Pressure relief valve The spring for the pressure relief valve (703) is configured for a system pressure of 175 +15 bar . By adding or removing shims, the pressure settings can be corrected. Shim 0.5 is approx. 10 bar Shim 1.2 mm is approx. 23 bar Note: These values are given to produce an average system pressure of 180 bar. After any adjustment or change, the system pressure must be checked. 03/2004 3-23