TIC LEXION 480-405 Standard machine functions Key to diagram 406 - Orifice plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ш 0.8 mm 734 - One-way valve (lock-up valve unit) Y33 - Solenoid valve for swinging out the unloading auger Y34 - Solenoid valve for swinging in the unloading auger T - Connection to tank P1 - Pump connection via returns valve A3 - Hydraulic ram for swinging out the grain tank unloading auger B3 - Hydraulic ram for swinging in the grain tank unloading auger K - Plunger Both sides of the ram are tightly locked by the lock valve (734) at the ports A and B.
Neutral function Function The relative solenoid valve (Y33/Y34) is operated depending on whether the unloading auger is being swung in or out. As well as one of these, the returns valve is also operated. The relative solenoid operates the plunger in the spool, which pushes the ball off its seat, and closes the flow to tank. The pressure then builds against the plunger (K) which in turn opens the lock valve (734) for connector A or B. The return flow from the ram flows back via the valve insert on the non operated solenoid valve (Y33/Y34) and back to tank. The pressure now builds up and opens the second lock valve (734). Oil now flows out through the lock valve and to the ram.
Pressure control Because of the nature of the unloading auger, when it is being swung in, it is necessary to limit the pressure to approx. 120 bar . Because of the requirement of the valve inserts and the relatively large size of pin, it is not enough to rely on the electromagnetic force of the solenoid to maintain system pressure. For this reason the pin sea in the valve unit will release oil to tank from 120 bar. Note : All 1999 machines have this facility fitted as standard. Should older machines be in need of this requirement, then a new valve insert can be fitted. 03/2004 3-29