TIC LEXION 480-405 Standard machine functions Key to diagram 309 - Concave left-hand hydraulic ram . . . . . . . . . . . Ш 40/22 mm 310 - Concave right-hand hydraulic ram . . . . . . . . . . Ш 50/30 mm A - Solenoid valve port for closing the threshing concave (close) B - Solenoid valve port for opening the threshing concave (open) V - Bottom valves Simultaneous function The two hydraulic rams are configured so that the surface area of the left hand ram (309) and that of the right hand ram (310) match. The system is designed so that regardless of load, the two rams travel in and out evenly.
Bottom valves The bottom valves (V) open whenever the rams reach their end stops, thus allowing air between the two rams to be bled. After a repair, the rams should be held in the end position for about 15 sec, thus allowing air to be exhausted. Note: The two hydraulic rams will after every 24 hours be switched to bleed the system every time the threshing has been switched on. Once the system has been bled the rams then travel back to the setting they were on before the bleeding process. 03/2004 3-37