CLAAS ACADEMY LEXION II Additional functions Key to diagram 502 - Accumulator for cross-levelling . . . . . . . . . . . . . 0.7 l / 80 bar 603 - Pressure relief screw 732 - One-way valve (delivery valve) 734 - Lock valve (lock-up valve unit) 740 - Flow control valve Y67 - Solenoid valve for cutterbar cross-levelling (left-hand side) Y68 - Solenoid valve for cutterbar cross-levelling (right-hand side) T - Tank port A7 - Hydraulic ram port for cutterbar cross-levelling (right-hand side) B7 - Hydraulic ram port for cutterbar cross-levelling (left-hand side) K - Plunger Caution:

When dismantling the positions 732, 502, 740, Y67 or Y68, the pressure must be released from the accumulator using the pressure relief screw (603). Function As soon as the cutterbar is switched on, the module for the CAC switches the returns valve on for 1 second. This will cause the system pressure to charge the accumulator (502) up via the one way valve (732). The CAC module will also switch the returns valve, should either solenoid valves (Y67/Y68) not be activated within a total of 10 seconds. This will ensure that the accumulator (502) is kept fully charged. The pressure in the system is locked up by the two ball valves of the solenoid valves (Y67/Y68).

The flow control valve (740) is there to ensure even flow with different pressures. Should there be the requirement to tilt the cutterbar, then the CAC module will send a signal down to one of the solenoids (Y67/Y68). The relative ball is pushed off its seat, and the return to tank is closed. The pressure then builds against the plunger of the lock valve, which then in turn opens the opposite valve (734) for port A or B. The return oil from the hydraulic rams is returned via the non switched solenoid valve (Y67/Y68) back to tank. The pressure then builds up against the opposite lock valve (734), which in turn opens allowing the oil to flow out to the hydraulic rams. Note:

Should the switching time for one of the solenoids (Y67/Y68) exceed 40 seconds, then the CAC module will switch off the supply. 11/2001 4-21