19-144 19-144 Electrical System Troubleshooting z Error codes H4-1, H4-2, H4-3, H4-4, H4-5 (Attachment 2 lever potentiometer abnormality) Related portion ECU-IG A23 7 (IG) 8 (IG2) AO3 YX1 XO2 Y3 Attachment 2 lever potentiometer SAS/OPS/ mini lever controller 10 (E44) A21 9 (E41) 10 (E42) 3 (E11) 4 (E12) Probable cause c Connector contact defect d Attachment 2 lever potentiometer harness defect e Attachment 2 lever potentiometer defect f SAS/OPS controller defect g Fuse defect Section 19 15 (AT21) 3 C C 7 C 4 3 (AT21) 16 (AT22) 2 E TAB TAB E 9 TAB E 5 2 (AT22) 26 (E1) 1 R R 3 R 7 1 (AT2-)