Toyota — Service Manual Change History

19-179 Electrical System Troubleshooting Section 19 Corrective action Harness check or replace switch Harness check or replace relay Change Replace Change Change Checking method ON/OFF check with analyzer Check the changeover status with an active test. Check the option set content. – Check the option set content. Check the option set content. Malfunction area · mode Lever change over switch unit: Ground short fault (Internal damage) Lever change over switch detection mechanism (mini lever): Detection part gap adjustment defect Lever change over switch line (signal): Ground short fault (Harness, connector) Lever change over relay 1 or 2 unit:

Stuck, welding fault (internal damage) Lever change over relay 1 or 2 primary side lower line: Ground short fault (wire, connector) Display setting: Number of attachment levers is not set to 5 way SAS/OPS controller: Controller defect Display setting: Number of attachment levers is not set to 2/3-way Display setting: Number of attachment levers is not set to 3-way (4-way) Phenomenon on vehicle Mini lever 3/4-way (2/3-way) change over specification: 4-way (3-way) continues to operate even though the lever change over switch has been operated. (Stays changed over) Mini lever 2/3-way change over specification:

During ATT1 operation and high lifting height, and when loaded, ATT1 stops and pull-side operation is slow. 3-way (4-way) specifcation: Although ATT1 (ATT2) is operated, it does not work. Control type Mini lever function