1B-24 AIR CONDITIONING Installation 1. Condenser Assembly Tighten: Inlet line to 15 N m (1.5 kg m/11 lb ft) If installing a new condenser, be sure to add 30cc (0.8 Imp fl oz) of new specified compressor oil to a new one. Tighten the outlet line to the specified torque. Tighten: Outlet line to 6 N m (0.6 kg m/4 lb ft) Tighten the condenser bolt to the specified torque. 2. Refrigerant Line O-rings cannot be reused. Always replace with new ones. Tighten the inlet line to the specified torque. Be sure to apply new specified compressor oil to the O-rings when connecting refrigerant line. Receiver / Drier (Except 4HK1-TC Engine Model For Australia) 4 2 1 3 N1A0080E Legend 1. Refrigerant line 3.
Receiver / drier 2. Pressure switch 4. Condenser assembly