Komatsu — SYSTEM COMPONENTS

OM4035.2 02/03 Maintenance - Section 4 Automatic Lube System Page 4- 15 SYSTEM COMPONENTS Flow Control Valve (8, Figure 3-1) The flow control valve mounted on the manifold, controls the amount of oil flow to the hydraulic motor. The flow control valve has been factory adjusted and the setting should not be disturbed. Filter (2, Figure 3-6) A filter assembly mounted on the right front upright filters the grease prior to refilling the reservoir from the shop supply. A bypass indicator alerts service personnel when the filter requires replacement.

Solenoid Valve (5, Figure 3-1) Hydraulic Motor and Pump (2 & 7, Figure 3-1) The solenoid valve, when energized, allows oil to flow to the hydraulic motor. Note: The pump crankcase oil level must be maintained to the level of the pipe plug port. If necessary, refill with 10W-30 motor oil. Vent Valve (6, Figure 3-2) Specifications are as follows: With the vent valve closed, the pump continues to oper- ate until maximum grease pressure is achieved. As this occurs, the vent valve opens and allows the grease pressure to drop to 0, so the injectors can recharge for their next output cycle. •Max. hydraulic oil inlet pressure: ..............................................

3,000 psi (20 685 kPa) •Hydraulic oil operating pressure: ..................................325-350 psi (2 240-2 415 kPa) 24 VDC Lubrication Cycle Timer (Not Shown) •Hydraulic inlet flow ............................................up to 7 GPM (28 L/min.) The lube cycle timer provides a 24 VDC timed-interval signal to operate the solenoid valve (5, Figure 3-1), causing the grease pump motor to operate. This timer is mounted in the cab (in the housing under the passenger seat) to insure temperature stability. •Pump ratio: approx. 9:1 ...@300 to 350 psi (2 068 to 2 415 kPa) oil pressure ............................

@less than 2 GPM (7 L/min.) flow •Operating temperature ....................................-20 to +150 ° F (-10 to +65 ° C) Pressure Switch (N.O. 2500 psi [17 237 kPa]) (Not Shown) The pressure switch, mounted on the front pump outlet port, energizes the normally closed pump solenoid relay when the grease line pressure reaches the switch pres- sure setting, turning off the motor and pump. Hydraulic oil supply inlet pressure must not exceed 3000 psi (20 685 kPa). Exceeding the rated pressure may result in damage to the system components and personal injury. Unloader Valve (Not Shown) The unloader valve is mounted on a “tee” fitting with the pressure switch described above.

This valve will relieve grease pressure in the pump if pressure exceeds 4000 psi (27.6 MPa). This valve has been factory adjusted and is not repairable. Grease Reservoir (1, Figure 3-2) The reservoir has an approximate capacity of 214 lbs. (97 kg) of grease. When the grease supply is replen- ished by filling the system at the service center, the grease is passed through the filter to remove contami- nants before it flows into the reservoir. Pressure Gauge (6, Figure 3-1) The pressure gauge monitors hydraulic oil pressure to the inlet of the hydraulic motor.

Pressure Reducing Valve (3, Figure 3-1) Manual Override (11, Figure 3-1) The manual override is used to actuate the hydraulic motor to manually activate a lubrication cycle. The pressure reducing valve, located on the manifold reduces the hydraulic supply pressure (from the truck steering circuit) to a suitable operating pressure, [325- 350 psi (2 240-2 415 kPa)] for the hydraulic motor used to drive the lubricant pump. Relay Box (4, Figure 3-2) The relay box houses the 24V relay used to control the solenoid valve controlling the hydraulic motor.