Maintenance - Section 4 OM4035.2 02/03 Page 4- 16 Automatic Lube System Injectors (11, Figure 3-2) 4. With oil flowing into the hydraulic motor, the grease pump will operate, pumping grease from the reser- voir to the injectors (13), and to the vent valve (11) and the normally open pressure switch (9). Each injector delivers a controlled amount of pressur- ized lubricant to a designated lube point. Refer to Figure 3-2 for locations. 5. During this period, the injectors will meter the ap- propriate amount of grease to each lubrication point.
This pressure switch will activate a Lube System Low Pressure Warning lamp on the overhead display if ade- quate grease pressure (2000 psi (13790 kPa)) is not attained within 1 minute. (Note: Warning system is optional on early model trucks.) Pressure Switch (27, Figure 3-2) 6. When grease pressure reaches the pressure switch setting, the switch contacts will close and energize the relay (3, Figure 3-4), removing power from the hydraulic motor/pump solenoid and the the pump will stop. The relay will remain energized until grease pressure drops and the pressure switch opens again or until the timer turns off. SYSTEM OPERATION Refer to Figure 3-3 & 3-4: 7.
After the pump solenoid valve (3) is de-energized, hydraulic pressure in the manifold drops and the vent valve will open, releasing grease pressure in the lines to the injector banks. When this occurs, the injectors are then able to recharge for the next lubrication cycle. 1. During truck operation, with the pump and timer systems in a rest state, a preset time interval oc- curs. 2. The lubrication cycle timer (1, Figure 3-4) provides a 24 VDC signal through the normally closed relay (3) used to energize the pump solenoid valve (4), allowing hydraulic oil provided by the truck steering pump circuit to flow to the pump motor and initiate a pumping cycle. 8.
The unloader valve (10) prevents excessive grease pressure if the pressure switch fails to close and shut off the hydraulic supply to the pump. The unloader will open at approximately 4000 psi (27.6 MPa). 3. The hydraulic oil pressure from the steering circuit is reduced to 325 to 350 psi (2 240 to 2 413 kPa) by the pressure reducing valve (4, Figure 3-3) before entering the motor. In addition, the amount of oil supplied to the pump is limited by the flow control valve (6). Pump pressure can be read using the gauge (5) mounted on the manifold. 1. Hydraulic Oil Return 2. Hydraulic Oil Supply 3. Pump Solenoid Valve 4. Pressure Reducing Valve 5. Motor Pressure Gauge FIGURE 3-3.
HYDRAULIC SCHEMATIC 6. Flow Control Valve 7. Hydraulic Motor 8. Grease Pump 9. Pressure Switch (N.O.) 10. Unloader Valve 11. Vent Valve 12. Orifice 13. Injector Bank